Operations and Maintenance Manual Mechanical Maintenance Procedures
Version 1.2 - June 2004 11 - 63
Note: The distance from the center of the upper sensor to the top of
the white counterbalance bracket should be 1 7/8 in. when
measured with a scale.
b. If the sensor trigger looks as if it will clip the sensor when moved
vertically, adjust the horizontal position of the sensor to permit the sensor
trigger to move vertically without touching the sensor trigger:
i. Using an adjustable wrench, loosen the one of the sensor's nuts by
rotating it counterclockwise.
ii. Slide the sensor in the slotted bracket as needed to position the sensor
to meet the Step 3. goal.
iii. Tighten the sensor nuts.