Operations and Maintenance Manual Mechanical Maintenance Procedures
Version 1.2 - June 2004 11 - 139
D. WHEN A SATISFACTORY ADJUSTMENT HAS BEEN ACHIEVED
1. Reconnect utility hoses.
2. Bolt the grinding section machine cabinet to the handling area section:
a. Rotate the handling section into place.
b. Replace a washer and wing nut on each setscrew and manually rotate each
wing nut clockwise to firm.
3. Reconnect the two black 2-inch exhaust duct tubes resting on the plenum to
the grinding exhausts located at the front of the grind chamber:
a. Match and connect each tube by squeezing to compress it.
b. When each tube is in position, release it.