1. Attach the keyboard to the control computer:
Note: The keyboard must be used to communicate with the Equipe robot
software.
a. Shut all machine power OFF by pulling the main machine disconnect
switch, located at the rear of the machine on the disconnect enclosure,
down to the off position.
b. Open door 8 and pull out the system unit’s support tray.
c. Plug the keyboard into the system unit’s keyboard connection.
d. Confirm that compressed air is ON.
e. Turn all machine power back ON by pulling the main machine disconnect
switch back up to the on position.
f. Press the <MACHINE ON> push button, located on the control panel, to
restore power to the machine’s controllers and subassemblies.
2. At the Main Menu, exit the 7AF control program:
You Type or Select Explanation/Screen Display
a. 7 At the Main Menu screen, touch the "7" in the
Model 7AF logo to return to the DOS prompt.
Displays:
DOS prompt
b. cd\ equipe <Enter> To move to the Equipe directory, at the DOS
prompt, type "cd\ equipe" and press the Enter key
to confirm.
Displays: C>EQUIPE
c. EQT <Enter> To load the Equipe software, type "EQT" and
press the Enter key to confirm.