Strasbaugh nTellect (Model 7AF) Wafer Grinder
13 - 44 Version 1.2 - June 2004
5. At the Output Control/Input Status menu, turn blow off ON to the left work
chuck:
Touch to Select Explanation/Screen Display
a. Inputs/Outputs At the Machine Maintenance menu screen, touch
the "Inputs/Outputs" button to select the Output
Control/Input Status menu.
Displays:
Output Control/Input Status menu
b. Left Work Chuck
icon Touch the "Left Work Chuck
icon", located in the Output Control section of
the menu, to display the Left Work Chuck drop
down menu.
(Right Work Chuck
icon)
c. Blow off ON/OFF Touch the "Blow off ON/OFF" button until
Blow off ON is displayed.
d. Close Touch the "Close" button to close the drop
down menu.
e. Quit Touch the "Quit" button to return to the
Machine Maintenance menu.
6. Rotate the knob on the Solenoid 20 regulator, located at the Door 14 Panel,
until the goal shown below is met:
GOAL: Set to produce gentle, even bubbling over the work chuck
surface.
CAUTION: Too high a pressure can destroy the work chuck and
damage the probe. Avoid production of violent bubbling or
mist.
(Right Work Chuck = Solenoid 24)