D950 Digital Mixing System
3-18 Desk Operation SW V3.3 Date printed: 03.09.03
D19m-MP4RC control parameters: On Page 4 of all input and output units, various functions of the D19m-
MP4RC quad mic/line input cards can be remote controlled (refer to
chapter 4.4.2.2 for details of how to activate/deactivate pre-amp remote
control).
LINE Selects the line-level input (mutually releasing the MIC-level input), with
gain setting in 35 steps of 1 dB, within a –9 through +25 dB range (de-
pendent upon the console’s current headroom and nominal level settings).
MIC Selects the microphone-level input (mutually releasing with the LINE-
level input), with gain setting in 60 steps of 1 dB, within a +15 through
+75 dB range (dependent upon the console’s current headroom and nomi-
nal level settings).
HPF An analog high-pass filter for the microphone-level input, with a fixed
cutoff frequency of 75 Hz and a slope of 12 dB/octave is available. The
SW key activates this filter.
48 V Selects Phantom Power ON/OFF for the microphone pre-amplifier.