Chapter 13 – Custom Logic
Firmware Version 3/4.31.37
The average temperature of that component for the current batch.
The average pressure of that component for the current batch.
The average density of that component for the current batch.
The average density of that component for the current batch.
The average density of that component for the current batch.
The gross amount delivered, of the specified component, which was not
authorized for the current driver.
The net amount delivered, of the specified component, which was not
authorized for the current driver.
The amount delivered in mass, of the specified component, which was not
authorized for the current driver.
The current vapor pressure of the specified component. The value is in
hundredths.
The percentage, of the specified component, for the current product recipe
that has been selected to load. The value is in whole units.
The volume amount, of the specified component, for the current product
recipe being loaded.
The calculated volume to be delivered, of a blended product, for the current
load.
The calculated percentage to be delivered, of a blended product, for the
current load.
The actual percentage, of the specified component, that has been delivered
for the current load. The value is in hundredths.
Blend Target Volume Error
The difference between the volume actually delivered, and the amount
intended to be delivered according to the Blend Target Recipe Percentage.
Blend Target Percentage Error
The difference between the percentage that was actually loaded, and the
Blend Target Percentage.
= Batch Recipe Percentage – Blend Target Percentage.
Batch Recipe Volume Error
The difference between the volume actually delivered, and the amount
intended to be delivered according to the recipe percentage.
Batch Recipe Percentage Error
The difference between the percentage of the recipe, and the percentage
that was actually loaded.
= Batch Recipe Percentage – Recipe Percentage.