Chapter 16 Firmware Revision History
479
Firmware Version 3/4.31.37
06/23/2013 WJP
Remove not batch_complete check from remote_clear input processing.
Added DEBUG_VOLUME and MEMORY_FILL test code.
07/02/2013 PS
Start new build x.31.12
For the creation of type 4 transaction record:
When loading in whole we only will generate a type4 transaction if the whole
value has a difference
When loading in hundredths we will only check the hundredths difference
Added also Net_whole and gross_hunds value for checking.
07/03/2013 PS
Enhancement that API 5X, 6X, 23X, 24X and 59/60X also support expansion coef
factor.
07/08/2013 PS
Enhancement split Vcf into Ctl and Cpl for Modbus, and all other protocols
Change Web-Interface and transaction viewer in MTL2 to show both values
Make these 2 new values available for Standalone Bol and for UAP Bol
Add these two values to the MRTD command.
Fix bug extra white line between net and mass totalizer on Web Interface page
Fix bug that Vcf didn't check API-TABLE to show the correct decimal place
Added Ctl, Cpl and Vcf to the MRS command
Added the Vcf , Ctl and Cpl to the Custom Logic
07/09/2013 WJP
Reset Preset Load Totals at Transaction Authorization.
07/13/2013 PS
Added Modbus TCP/IP Protocol on port 502
Added Phase 1 Alibilog Screen and Bol Position Screen
Restrict send Modbus Command to 1000 Registers (instead of 32768)
07/16/2013 PS
Phase 2 Bol Position Screen make it possible to print bol sample to verify
configuration
07/24/2013 PS
Enhance the webpage transaction viewer will not show any more ctl,cpl and ctpl
for saleable product
Enhance the webpage simulation page if additive exists we don't show the same
port again
Enhance the webpage so that when we have a meter connected to the fcm it does not
show 2 times port 4
Enhance the webpage so that when we have a meter with quadrature we don't show 2
times port 5
Enhance transaction viewer don't show exp coef. or corrected
density/gravity/relative when not applicable
07/25/2013 PS
New enhancement additive tolerance percentage if used, additive check by
injection size can be still used at the same time.
Added excess flow timer for preset and meter level, if timer zero fcm does the
check if timer used MTL2 will do the check.
Added Additive volume start check so before we will not check the additive
injection combined with additive tolerance check