Chapter 16 Firmware Revision History
483
Firmware Version 3/4.31.37
Updated Auto Batch authorize to not switch to the control screen when a remote
start is configured.
Corrected bug in Auto authorization where multiple presets running auth
authorization at the same time would not work.
10/15/2013 WJP
Updated UAP TDS record download to space fill if the record received from TDS is
smaller than the record size defined in the database table.
10/25/2013 PS
Increased version number to x.31.14
Enhancement of Custom Logic:
Ability to read any configuration parameter Rcu, Bay, Preset, Meter, Component
and Additive Level.
Ability to write any configuration parameter Rcu, Bay, Preset, Meter, Component
and Additive Level. But if it is a W&M parameter,
the W&M bolt needs to be out, otherwise no update is possible.
FCM Output Value in Diagnostic will only show a 0 or 1.
Added Groups in Custom Logic to easier find functions. Timer, Alarm, Config
Read, Config Write, Operations Groups.
Added new custom_logic values to all protocols as also Modbus.
10/26/2013 PS
Added W&M ID for Custom Logic "L", so if a W&M parameter gets updated via Custom
Logic it will log this in the W&M Log.
Custom Logic can only update W&M config if the W&M bolt is not inserted!
10/27/2013 PS
Enhancement NEW Hazard screen gives the ability to change the hazards on the
MultiLoad Screen.
10/28/2013 PS
Added all 2007 API E-tables Gas Products.
10/31/2013 WJP
Fixed startup issue where if power was removed during the initialization of the
MultiLoad hardware, the previous state could be lost,
preventing a currently active transaction at the time of initial power failure to
not be restored correctly.
This could cause loss of the currently active transaction data.
Fixed bug where after firmware upgrade, ML could get stuck in load screen until a
factory reset was done.
Corrected CN bug where a missing transaction data would prevent ML from sending
any further data packets to TDS causing a communication loss.
11/01/2013 PS
Enhancement Printing Menu has now also option to change the standalone prompts.
11/4/2013 TF
Added CRC checksum to firmware image.
Added startup CRC checksum verification against stored firmware flash image on
startup.
Added CRC checksum verification before loading new firmware image into flash (if
it contains a checksum).
11/04/2013 PS
Adding the VSX Database to UAP.
TODO: Logic of VSX/VSE.