Chapter 16 Firmware Revision History
485
Firmware Version 3/4.31.37
12/13/2013 PS
Added for all 2004 API Tables the Compressibility Factor (Fp).
Enhanced the VCF SETUP calculator to show the Compressibility Factor.
Added pressure input to all 2004 API Tables with UOM Selection. Remark: Density
and Temperature are fixed to API Type.
Added for all 2007 E API Tables the Compressibility Factor (Fp).
Added help for parameter Compressibility Factor.
Fix: VCF SETUP Screen supports now negative API Gravity and Pressure.
Fix: The correct relative density for 2004 Tables. Could be of by 1 point and
this was only for the display. Also did not affect vcf.
12/15/2013 PS
Fix: 2004 API 6X,24X,5X,23X should not have a reference temperature.
Fix: All 2004 API X-Tables couldn't handle different uom density types.
Enhance the VCF Setup Screen with combining uom with values.
Enhance the 2007 59E and 60E Table to support correction to reference
temperature.(So 20 degrees or 30 degrees can be used now).
Enhance on the bay configuration level the selection of temperature from
disable/enable to C/F.
Changing help description for Temperature UOM.
Fix: UOM expansion label type.
Added auditlog checking to VCF Setup Screen.
Added auditlog to Temperature, Pressure, Density, Relative Density, BSW1, BSW2,
API Gravity, Mass Calc Screen.
12/19/2013 PS
Added additive mode: Start injection when batch starts, Start injection when
going to HIGH FLOW, Start injection when exceeding start/restart volume.
Added additive start and restart volume parameter. Also added the help for these
parameters.
Fix: For Register R800 and MRTD command. When using the relative density this
would shift the output string. The resolution is that at the end of both
we added the relative density/density/gravity so i can reflect the full value.
The old register is secured that it will not go higher than 9999.
12/27/2013 PS
Fix: Unauth Flow Voucher supports now hundredths.
Enhancement EOD Report will only show mass if used.
1/3/2014 TF
Fix: Modbus, reading, and writing of alarm parameters. Custom Logic enable flag
was not being accounted for.
Fix: When loading from a configuration file, ensure Custom Logic value is within
range if enabled for any FCM I/O parameter. Value is discarded otherwise.
1/7/2014 PS
Added Alt. High Flow Status to the Custom Logic Section.
Added Fallback Rate to Custom Logic Section, under component level.
1/7/2014 WJP
Added UAP VSX/VSE processing logic.
1/17/2014 PS
Increase firmware to x.31.15
Enhancement support now fully decimal versus comma, also parameter help added.
Enhancement Custom Logic added preset whole volume, flush volumes, blend values.
Enhancement of Custom Logic that divide by zero is not possible.