Firmware Version 3/4.31.37
1/31/2014 WJP
Added Open Loading for Germany Local Requirement.
New Preset Parameter "Open Loading" added, when enabled will prompt for a
Compartment Preset volume (sub batch size). This can be done until the Batch
preset volume is reached. All compartments will recorded in one batch on the
transaction. This will work in standalone or remote processing modes without
special host support.
1/31/2014 PS
Added help for Open Loading.
2/7/2014 TF
Enhancement: Save the Network configurations, if they are enabled, during factory
reset.
Fix: Typo in the meter functions. "Preset xx, End Batch Received Earily."
2/14/2014 WJP
Corrected bug in Audit Log Archive routine where a directory pointer was closed
twice. While this could cause a crash on all SD card platforms, but crashes were
only observed on Linux and android platforms.
2/07/2014 PS
Fix: Length of the prompt can never exceed 25, enhanced with limit check.
3/03/2014 PS
Additive Input Permissive is now conditional W&M, when additive W&M is enabled.
Custom Logic has now the card_number as facility code available for any type of
card reader selected. Remark: Ibutton is converted from hex to decimal.
Also Custom Logic will support dual card processing in custom logic.
3/04/2014 PS
Changed default of Additive Enabled to Enabled instead of Disabled.
Added on Preset Level an Enable/Disable option so when the arm is not used the
preset can be disabled and no alarms are getting generated when no FCM is
available.
If Preset or Additive is disabled we will not check the fcm assignments.
Added help for Preset Enable Parameter.
Added Fallback Minimum Pressure, this parameter will try to ensure that a minimum
back pressure on the line is maintained. Steps down by deadband and in retry mode
it will step up by deadband.
If this pressure control is used the Fallback Rate will be not used.
Added help for all new Fallback parameters.
Change all configuration pressure values from whole to hundredths values.
Enhanced Diagnostic selection of Preset as Additive if one of these 2 are
disabled the diagnostic screen will show the user.
Added new Flow Rate parameter to see flowrate in minutes or in hours.
Increase FCM Firmware revision to 41.
Enhanced Prompt Screen so it shows the Language name instead of the Language
number.
Added parameter to hide preset totalizers on preset screen.(Display Preset
Totalizer)
Added check that we don't allow open-loading for sequential loading.
Added German translation for Open Loading.
Fix: We will not check blend tolerance when load is not authorized anymore.
Adding MCBA command to clear bay alarms for all protocols. Also added FMCBA
command to clear bay alarms.
Fix: Compartment number payload to UAP.