Firmware Version 3/4.31.37
06/30/2015 TF
Fix: In version x.31.23 (MultiLoad and SCS Builds) if Display Hundredths, Use
Hundredths, or Proving Mode were enabled, the MultiLoad would continuously redraw
the Delivered Amount on the Preset/Line Control Screen.
06/30/2015 MS
Enhancement: Added Hi Limit FCM as Sampler input. Used to alert to full sample
pot. Result becomes a "HI LIMIT" alarm for the selected product with an inhibited
ability to load/offload further product.
07/01/2015 TF
Added the ability to configure the SCS Prompts to be displayed before or after
the transaction.
Added a new parameter, "SCS Prompting Display" to the RCU Setup Menu.
Fix: Observed values in the View Transaction Details screen. The screen would
display "Type: Unknown", and wouldn't display the Observed Gross or the Observed
Temp.
Fix: The Observed Values were not being reset after each transaction. If the user
configured a certain set of Observed Prompt to be displayed and then decided to
change them, it was possible that a previous entry would show up on the on the
transaction detail.
07/01/2015 MS
Fix: Suppress Reprint prompt if no printer is configured in com or network
settings.
07/02/2015 TF
Enhancement: The MultiLoad will now automatically backup the configuration,
during bootup or after exiting program mode, or any time a configuration change is
made.
- These files can be automatically FTP pushed to an external server if FTP is
enabled.
- The file name will have the Terminal Name, Bay Number, Date Stamp, and a
Time stamp.
- Added New SD Card Configuration Parameters: "Auto Save Config in Days" and
"Save All Config Changes". "Auto Save Config in Days" allows the user to configure
how frequently the MultiLoad will automatically backup the config. "Save All Config
Changes" allows the user to ENABLE or DISABLE whether the MultiLoad saves the
config every time a change is made.
Added a new directory called "CONFIGURATIONS". This is where all backup configs
will be stored.
Added a new Custom Logic RCU R.T. parameter "Config Changed". This can be used as
a flag in custom logic to know when a parameter has changed, it will be reset once
the configuration has been saved.
Moved the Parameter "Save Transactions to SD Card" from the RCU Level to the SD
Card Configuration Level. If this parameter was used on a previous build, the user
will need to go to the SD Card Configuration screen to Enable it again. Simply
Loading the old configuration file will not work, if the version is less than
v4.31.24.
07/02/2015 MS
Fix: Suppress Print prompt in Transaction View if no printer is configured in com
or network settings.
07/10/2015 TF
Fix: SMP Load Screen was broken in v23. The delivered volume showed up in the upper left
hand corner of the screen.