EasyManuals Logo

Edge-Core ECS4610-24F User Manual

Edge-Core ECS4610-24F
1154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #635 background imageLoading...
Page #635 background image
C
HAPTER
25
| SNMP Commands
– 635 –
COMMAND USAGE
â—† If you do not enter an snmp-server host command, no notifications
are sent. In order to configure the switch to send SNMP notifications,
you must enter at least one snmp-server host command. In order to
enable multiple hosts, you must issue a separate snmp-server host
command for each host.
â—† The snmp-server host command is used in conjunction with the
snmp-server enable traps command. Use the snmp-server enable traps
command to enable the sending of traps or informs and to specify
which SNMP notifications are sent globally. For a host to receive
notifications, at least one snmp-server enable traps command and the
snmp-server host command for that host must be enabled.
â—† Some notification types cannot be controlled with the snmp-server
enable traps command. For example, some notification types are
always enabled.
â—† Notifications are issued by the switch as trap messages by default. The
recipient of a trap message does not send a response to the switch.
Traps are therefore not as reliable as inform messages, which include a
request for acknowledgement of receipt. Informs can be used to ensure
that critical information is received by the host. However, note that
informs consume more system resources because they must be kept in
memory until a response is received. Informs also add to network
traffic. You should consider these effects when deciding whether to
issue notifications as traps or informs.
To send an inform to a SNMPv2c host, complete these steps:
1. Enable the SNMP agent (page 630).
2. Create a view with the required notification messages (page 640).
3. Create a group that includes the required notify view (page 637).
4. Allow the switch to send SNMP traps; i.e., notifications (page 633).
5. Specify the target host that will receive inform messages with the
snmp-server host command as described in this section.
To send an inform to a SNMPv3 host, complete these steps:
1. Enable the SNMP agent (page 630).
2. Create a local SNMPv3 user to use in the message exchange
process (page 639).
3. Create a view with the required notification messages (page 640).
4. Create a group that includes the required notify view (page 637).
5. Allow the switch to send SNMP traps; i.e., notifications (page 633).
6. Specify the target host that will receive inform messages with the
snmp-server host command as described in this section.
â—† The switch can send SNMP Version 1, 2c or 3 notifications to a host IP
address, depending on the SNMP version that the management station
supports. If the snmp-server host command does not specify the
SNMP version, the default is to send SNMP version 1 notifications.

Table of Contents

Other manuals for Edge-Core ECS4610-24F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS4610-24F and is the answer not in the manual?

Edge-Core ECS4610-24F Specifications

General IconGeneral
BrandEdge-Core
ModelECS4610-24F
CategoryNetwork Router
LanguageEnglish

Related product manuals