2 - 67
Chapter 2 Troubleshooting
FIP-1.29 024-362: IOT Start Image Marking Time-out
Step Check
Remedy
Yes No
Possible causative parts:
PWBA ESS AIO (PL8.1.2)
1
Checking the firmware version
Is the firmware the latest version?
Go to step 2.
Upgrade the
firmware, then go
to step 2.
2
Checking the error.
Does the error still occur when printing?
Replace the KIT
PWBA ESS AIO.
(Refer to REP8.2.)
End of work.