4 - 182
Chapter 4 Disassembly / Assembly and Adjustments
REP6.3TRANSFER ASSY (PL6.1.7), COVER HARNESS (PL6.1.8)
[Removal]
1) Remove the CASSETTE ASSY 250 MG AIO. (REP2.1)
2) Open the COVER ASSY FRONT (PL1.2.1).
Cover the drum of the PHD ASSY to avoid exposure to light.
3) 3) Remove the PHD ASSY. (REP4.6)
The FUSING UNIT part is very hot. Take added care not to get burned when
performing the service operation.
4) Remove the FUSING UNIT. (REP6.1)
5) Remove the COVER ASSY SIDE R AIO. (REP1.8)
6) Remove the COVER ASSY SIDE L AIO. (REP1.9)
7) Close the TRANSFER ASSY (PL6.1.7).
When carrying out the work described next procedure, take care not to scratch
the belt surface of the TRANSFER ASSY.
When carrying out the work described below, leave the relay connector on the
TRANSFER ASSY harness side.
8) Release the hooks of the COVER
HARNESS (PL6.1.8), using a minia-
ture screwdriver, and then remove
the COVER HARNESS.