Chapter 4 Disassembly / Assembly and Adjustments
REP8.6 SENSOR HUM (PL8.1.10)
[Removal]
1) Remove the CASSETTE ASSY 250 MG AIO. (REP2.1)
2) Open the COVER ASSY FRONT (PL1.2.1).
NOTE
Cover the drum of the PHD ASSY to avoid exposure to light.
3) Remove the PHD ASSY. (REP4.6)
NOTE
The FUSING UNIT part is very hot. Take added care not to get burned when
performing the service operation.
4) Remove the FUSING UNIT. (REP6.1)
5) Remove the COVER ASSY SIDE L AIO. (REP1.9)
6) Remove the one screw (silver, tap,
8mm) that fixes the SENSOR HUM
(PL8.1.10) to the printer, remove the
SENSOR HUM.
7) Disengage the connector (P/J201) of
the SENSOR HUM.