3 - 48
Chapter 3 Image Quality Troubleshooting
FIP-1.P22 Label Stuck
.Possible causative parts
- FUSING UNIT (PL6.1.1)
Before commencing troubleshooting, check the paper transfer path. Make sure there is no foreign
materials on the transfer path, such as staples, paper clips, scraps of paper and so on.
Step Check
Remedy
Yes No
1
Checking for foreign materials around the paper transfer
path.
Are there any foreign materials such as precut adhesive
labels in the the paper transfer path?
Remove the
foreign materials.
Warning: Start the
operation after the
FUSING UNIT has
cooled down.
Replace the
FUSING UNIT.
(Refer to REP6.1.)
After replacement,
be sure to clear
the life counter