4 - 48
Chapter 4 Disassembly / Assembly and Adjustments
REP1.12 SHAFT PIVOT (PL1.2.14)
[Removal]
1) Remove the CASSETTE ASSY 250 MG AIO. (REP2.1)
2) Open the COVER ASSY FRONT (PL1.2.1).
3) Release the hook of the SHAFT
PIVOT (PL1.2.14), pull out the left
side SHAFT PIVOT.
4) Release the hook of the SHAFT
PIVOT, pull out the right side
SHAFT PIVOT.
5) Release the hook of the SHAFT
PIVOT, pull out the SHAFT PIVOT
that is the fixation of the LINK
ASSY FRONT AIO (PL1.2.28).