6 – 40
Chapter 6 General
1182
Dup Speed3 Transfer Voltage Correction Value
PlainPaper-L
0-255 - 00 0
1183
Dup Speed3 Transfer Voltage Correction Value
PlainPaper-H
0-255 - 00 0
1184
Dup Speed3 Transfer Voltage Correction Value
CotedPaper-L
0-255 - 00 0
1185
Dup Speed3 Transfer Voltage Correction Value
CotedPaper-M
0-255 - 00 0
1186
Dup Speed3 Transfer Voltage Correction Value
CotedPaper-H
0-255 - 00 0
1187
Dup Speed3 Transfer Voltage Correction Value
HeavierPaper-L
0-255 - 00 0
1188
Dup Speed3 Transfer Voltage Correction Value
HeavierPaper-H
0-255 - 00 0
1189 Dup Speed3 Transfer Voltage Correction Value Envelope 0-255 - 00 0
118A Dup Speed3 Transfer Voltage Correction Value Postcard 0-255 - 00 0
118B
Dup Speed3 Transfer Voltage Correction Value
Transparency
0-255 - 00 0
118C Dup Speed3 Transfer Voltage Correction Value Label-L 0-255 - 00 0
118D Dup Speed3 Transfer Voltage Correction Value Label-H 0-255 - 00 0
118E Dup Speed3 Transfer Voltage Correction Value Thicker 0-255 - 00 0
118F Dup Speed3 Transfer Voltage Correction Value Recycled 0-255 - 00 0
1190 Dup Speed3 Transfer Voltage Correction Value Custom1 0-255 - 00 0
1191 Dup Speed3 Transfer Voltage Correction Value Custom2 0-255 - 00 0
1192 ROS Time Out (sec) 0-30 sec 05 5
1193 FUSER Time Out (Min) 0-120 min 3C 60
11A6 High Altitude Offset Value (Trans) [0] 0-255 - 00 0
11A7 High Altitude Offset Value (Trans) [1] 0-255 - 00 0
11A8 High Altitude Offset Value (Trans) [2] 0-255 - 00 0
11A9 High Altitude Offset Value (Trans) [3] 0-255 - 00 0
11AA High Altitude Offset Value (Xero) [0] 0-255 - 00 0
11AB High Altitude Offset Value (Xero) [1] 0-255 - 04 4
11AC High Altitude Offset Value (Xero) [2] 0-255 - 06 6
11AD High Altitude Offset Value (Xero) [3] 0-255 - 08 8
11AE
High Altitude Offset Mode (common)
MODE0(0): altitude of 0[m] default
MODE1(1): altitude of 1000[m] below
MODE2(2): altitude of 1000[m]-2000[m]
MODE3(3): altitude of 2000[m]-3500[m]
0-255 - 00 0
11AF
XERO Idling Sequence Execution Counter (Command
6F)
0-255 - 00 0
11BC Deve Idling Time Timer Counter[s] (Command 7F) 60 sec 0-255 sec 3C 60
11C0 PV requirement for operating CL1 High 0-255 - 01 500
11C1 PV requirement for operating CL1 Low 0-255 - F4 -
11C2 Temperature Difference requirement for operating CL1 0-255 - 04 4
1606 Regi Con Sample Block Error details (Process) 0-255 - 00 0
1607 Regi Con Sample Block Error details (Lateral) 0-255 - 00 0
Add
(Hex)
Remarks Range Unit
Default