6 – 124
Chapter 6 General
(6) Parameter
This function reads/writes the following parameters stored in the printer.
Print the parameter list using the Print function of Parameter Menu in diagnosis
before changing the value of the registration.
Item Range Description
Slow Scan K to P
-128 to 127
Sets the registration in the paper feeding direction
Slow Scan 600 M,Y,C
Fast Scan K to M,Y or C
-128 to 127
Sets the registration in the scanning direction.Fast Scan M-Feed ,Tray
-30 to 30
Fast Scan 2 K to M,Y or C
-1 to 2
Life Counter
-
Reads the life counter and the printer.
Parameter Function Default
Adjustable
range
Slow Scan K to P
(Shifts 0.17mm/1count)
Black registration adjustment
-- -128 to 127
Slow Scan 600 M,Y,C
(Shifts 0.042mm/1count)
Color registration adjustment (600 dpi)
-- -128 to 127
Fast Scan K to M, Y or C
(Shifts 0.042mm/1count)
Color registration adjustment Calculation of
adjustment is shown below.
(exp. Yellow)
(Value of Fast Scan K to Y + Value of Fast Scan 2
K to Y )/4
-- -128 to 127
Fast Scan 2 K to M, Y or C
(Shifts 0.01mm/1count)
-- -1 to 2
Fast Scan M-Feed, Tray
(Shifts 0.17mm/1count)
Black registration adjustment at side 1 print
-- -30 to 30