Release the screw (see circle).
â–¶
Pull the HDD backplane upward until the two hooks disengage (see orange
circles).
â–¶
Take out the HDD backplane.
Installing the new 8x 2.5-inch HDD backplane
Figure 86: Installing the 8x 2.5-inch SAS HDD/SSD backplane
â–¶
Position the HDD backplane on the two hooks (see orange circles).
â–¶
Push the HDD backplane downward. Make sure that the HDD backplane fits
into the guide pins.
â–¶
Fasten the screw (see circle).
â–¶
If applicable, install the internal RAID riser module, see "Installing the
internal RAID riser module" on page
271
.
â–¶
If applicable, install the SAS expander board holder, see "Installing the SAS
expander board holder" on page 206.
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M6 Upgrade and Maintenance Manual 181

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2540 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX2540 M6 Specifications

General IconGeneral
Memory Slots32 DIMM slots
Form Factor2U rack server
ProcessorIntel Xeon Scalable Processors (3rd generation)
StorageUp to 24 x 2.5" or 12 x 3.5" drives
RAID SupportRAID 0, 1, 5, 6, 10
Network4 x 1GbE ports (onboard), optional 10/25GbE
Power Supply800 W, 1200 W, 1600 W
Expansion SlotsUp to 8x PCIe Gen4 slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware