Operation Manual – SNMP-RMON
H3C S3100 Series Ethernet Switches Chapter 2 RMON Configuration
2-4
Operation Command Description
Add an
extended
alarm entry
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-timer { delta | absolute |
changeratio } rising_threshold
threshold-value1 event-entry1
falling_threshold threshold-value2
event-entry2 entrytype { forever |
cycle cycle-period } [ owner text ]
Optional
Before adding an
extended alarm entry,
you need to use the
rmon event command to
define the event to be
referenced by the
extended alarm entry.
Enter
Ethernet port
view
interface interface-type
interface-number
—
Add a history
entry
rmon history entry-number buckets
number interval sampling-interval
[ owner text ]
Optional
Add a
statistics entry
rmon statistics entry-number [ owner
text ]
Optional
 Note:
z The rmon alarm and rmon prialarm commands take effect on existing nodes only.
z For each port, only one RMON statistics entry can be created. That is, if an RMON
statistics entry is already created for a given port, you will fail to create another
statistics entry with a different index for the same port.
2.3 Displaying RMON
After the above configuration, you can execute the display command in any view to
display the RMON running status, and to verify the configuration.