Operation Manual – Information Center
H3C S3100 Series Ethernet Switches Chapter 1 Information Center
1-9
 Note:
z If the system information is output before you input any information following the
current command line prompt, the system does not echo any command line prompt
after the system information output.
z In the interaction mode, you are prompted for some information input. If the input is
interrupted by system output, no system prompt (except the Y/N string) will be
echoed after the output, but your input will be displayed in a new line.
1.2.3 Configuring to Display the Time Stamp with the UTC Time Zone
To add UTC time zone to the time stamp in the information center output information,
you must:
z Set the local time zone
z Set the time stamp format in the output direction of the information center to date
z Configure to add the UTC time zone to the output information
Table 1-6 Configure to display time stamp with the UTC time zone
Operation Command Description
Set the time zone for the
system
clock timezone
zone-name { add | minus }
time
Required
By default, UTC time
zone is set for the
system.
Enter system view
system-view
—
Log host
direction
info-center timestamp
loghost date
Set the time
stamp format in
the output
direction of the
information
center to date
Non log
host
direction
info-center timestamp
{ log | trap | debugging }
date
Required
Use either command