Default timing
You can press the Time key to open the Time Defaults window. Here you can set the times that will be used as
a default when you create new cues.
Set a time when storing
You can overwrite the default timing when you store a cue. E.g. you want to store cue 3 with a fade time of 5
seconds: Store Cue 3 Time (= Fade command) 5 Please .
The Time key have a special function when you use it in a command. In the above example you can keep
pressing the Time key to change between the different available timings in the cue - although not the preset
type timings.
Change timing in Cues view
When you have a Cues view visible then you can press and hold on a value in the view to change the time value.
You can also use the scroll encoder to select the time field you want to change and then tap the encoder. This will
give you the Calculator view. Use this to set the new value.
You can also press the Edit key and then the field in the Cues view that you want to change, this also gives you
the Calculator view.
Cue triggers
Each cue have a trigger. This is what makes the cue run. There are several triggers:
Go - The cue only triggers when it gets a Go command.
Time - When you select Time, then you need to specify the time in the Trig Time column. The time you set will
begin to count down when the previous cue is triggered.
Follow - A follow cue will trigger when the previous cue is done with all the fades.
Sound - The sound trigger is triggering the cue when the console receives sound spikes. You'll find different
sound options in the "Trig Time" column. The options called "Snd" and then a number is different set
frequencies. You can see the incoming sound in the Sound Input Configuration view, found in the Tools Menu.
BPM - The cue can be triggered based on the measured BPM from the sound input. This can also be seen in
the Sound Input Configuration view.
Timcode - Your cue can be triggered by incoming time code signal. You need to set the trigger time in the "Trig
Time" column. The timecode used can be set in the Settings of Executor view. The timecode can be recorded -
please read more about this in the Cue view.
Important
When a cue is triggered by timecode then the cue is always Asserted. This means that all tracked
values are asserted when the cue is triggered.