Managing programs
13.18 RS-232-C
Turning
784 Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
V24 setting
Meaning
End of data transfer (hex) Only for punched tape format
Stop with end of data transfer character
The default setting for the end of data transfer character is (HEX) 1A
Time monitoring (sec) Time monitoring
For data transfer problems or at the end of data transfer (without end
of data transfer character) data transfer is interrupted after the speci-
fied number of seconds.
The time monitoring is controlled by a time generator (clock) that is
started with the first character and is reset with each transferred char-
acter.
The time monitoring can be set (seconds).
Procedure
1.
Select the "Program Manager" operating area.
2.
Press the "NC" or "Local drive" softkey.
3.
Press the ">>" and "Archive" softkeys.
4.
Select the "V24 settings" softkey.
The "Interface: V24" window is opened.
5.
The interface settings are displayed.
6.
Press the "Details" softkey if you wish to view and process add
i-
tional settings for the interface.