Alarm, error and system messages
14.1 Displaying alarms
Turning
786 Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
Select the "Diagnostics" operating area.
Press the "Alarm list” softkey.
The "Alarms" window appears.
All pending alarms are displayed.
The "Hide SI alarms" softkey is displayed if safety alarms are pending.
Press the "Hide SI alarms" softkey if you do not w
ish to display SI
...
Position the cursor on an alarm.
Press the key that is specified as acknowledgement symbol to d
elete
Press the "Delete HMI alarm" softkey to cancel an HMI alarm.
Press the "Acknowledge alarm" softkey to delete a PLC alarm of the SQ
type (alarm number as of 800000).
ed when the cursor is on the corresponding
Turn the unit off and back on (main switch), or press NCK POWER ON.
Press the <RESET> key.
...
Press the <ALARM CANCEL> key.
- OR -
Press the "Acknowl. HMI alarm" softkey.