Fade to Black
Knob
Parameter
Adjustment
Setting values
1
Transition
Rate
Transition rate
0 to 999 (frame
count)
Chapter
3
Signal
Selection
and
Transitions
If required, press the [TC] button to switch the input
mode (frame count input or timecode input).
Enter a value of up to three digits.
To cancel the input, press any of the mode selection
buttons.
6
Press the [ENTR] button.
Setting the independent key transition rate
by a menu operation
1
In the M/E or PGM/PST menu, select first the desired
one from VF1 ‘Key1’ to VF4 ‘Key4,’ then HF6
‘Transition.’
The Transition menu for the selected key appears.
2
Select any transition type in the <Transition Type>
group.
If, in the Setup menus, you set insertion/deletion as
independent modes, make the settings for insertion in
the <On Transition Type> group, and the settings for
deletion in the <Off Transition Type> group.
3
Turn the knob to set the transition rate.
Independent key transition rate display
To check the set independent key transition rate, press the
key source name display/key snapshot button above the
corresponding delegation button when the [K-SS] button is
off.
Displaying the independent key transition
rates in a menu and changing the settings
For each of the M/E and PGM/PST banks, you can also
display the transition rate, independent key transition rate
and fade-to-black transition rate, and change the settings
(see page 234).
Fade to Black
The PGM/PST block provides a fade-to-black function for
the program output image.
Notes
In multi-program mode or DSK mode, it is possible to
carry out a fade-to-black on a number of programs
simultaneously.
You can also make a Setup menu setting such that a fade-
to-black does not apply to particular programs.
For details of the setting, see “Settings Relating to Video
Switching (Transition Menu)” in Chapter 20 (Volume 2).
Fade to Black Operation
Fade-to-black transitions can be executed using the [FTB]
button in the fade to black control block.
FTB button
Fade to black control block
Carrying out a fade to black
Press the [FTB] button.
The fade to black is carried out with the transition rate set
for the program output of the PGM/PST bank.
During the transition, the [FTB] button lights amber. When
the transition completes (the video is completely black),
the button lit color changes to red.

Table of Contents