Control of P-Bus Devices 419
Chapter
12
External
Devices
3
Enter the register number for which you want to carry
out the Learn.
The setting range is from 1 to 250.
4
Press [Enter].
4 Press the [ENTER] button in the numeric keypad
control block.
P-Bus Trigger
“P-Bus trigger” is a function whereby a button operation in
the numeric keypad control block or keyframe control
block outputs an action command to a P-Bus device.
Notes
To use the P-Bus trigger function, the P-Bus control mode
must be set to [Trigger]. Make this setting in the
Engineering Setup >Panel >Device Interface menu.
For details, see “Setting the Control Mode for P-Bus
Devices (page 600).
The relation between the operation in each of the control
blocks and the action command output is as follows.
Action command for an operation in the numeric
keypad control block or Multifunction Flexi Pad
control block
RECALL: Recall
STORE: Store
This recalls the register specified in the numeric keypad
control block, and a Recall or Store is carried out,
according to the setting.
Action command for an operation in the keyframe
control block or Multifunction Flexi Pad control
block
RUN: Trigger 1
REWIND: Trigger 4
NEXT KF: Trigger 7
PREV KF: Trigger 8
Outputting an action command
As an example, to output a Recall, use the following
procedure.
1
In the numeric keypad control block, press the [EFF]
button, turning it on.
The [RCALL] button in the numeric keypad control
block lights.
2
Press the [P-BUS] button in the numeric keypad
control block, turning it on, to select the P-Bus region.
3
Enter the number of the register (1 to 250) to be
recalled with the numeric keypad buttons.