Parallel Tally Settings (Parallel Tally Menu) 657
Knob
Parameter
Adjustment
Setting values
1
Copy From
Copy-from source
1 to 1024
2
Copy To
Copy-to source
1 to 1024
Chapter
23
Setup
Relating
to
Router
Interface
and
Tally
(Router/Tally)
3
Press [Execute].
Parallel Tally Settings
(Parallel Tally Menu)
For settings relating to parallel tally, use the Router/Tally
>Parallel Tally menu.
Deleting Tally Copy Settings
1
In the Router/Tally >Tally Copy menu, using any of
the following methods, select the tally copy whose
settings you want to delete.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knob.
Knob
Parameter
Adjustment
Setting values
1
Copy No
Tally copy setting
selection for
deletion
1 to maximum
value
2
Press [Delete].
Make the parallel port settings for output of tally
information pertaining to sources and destinations.
For each of the tally output terminal numbers, specify the
tally type, and source address or destination level and
address.
To display the Parallel Tally menu
In the Engineering Setup menu, select VF6 ‘Router/Tally
and HF6 ‘Parallel Tally.’
The status area shows the parallel tally settings.
Making or Modifying Parallel Tally
Settings
1
In the <Device> group of the Router/Tally >Parallel
Tally menu, select DCU1 or DCU2.
2
Using any of the following methods, select the slot
number and port number.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knobs.
Knob
Parameter
Adjustment
Setting values
1
Slot No
Parallel tally slot
number
2 to 6
a)
2
Port No
Parallel tally port
number
1 to 54
b)
a)
When the MKS-2700 is connected, select 2 for the slot.
b)
When the MKS-2700 is connected, select a value in the range 1 to 36.
3
Press [Set].
The Set menu appears.
4
In the <Source/Destination> group, select the tally
type.
Src: Return a tally to all sources output to the
destination.
Dest: Return a tally to the destination outputting the
source to which a source tally is returned.
5
Set the destination address and level.
The level setting is only required when in step 4 you
selected Destination.