Interfacing With External Devices (Device Interface Menu) 631
Chapter
20
Switcher
Setup
(Switcher)
bus from the DME (DME-3000/7000) connected to these
ports.
At this time, connect the DME input video signals and key
signals as follows.
DME1 video input: AUX1 output
DME1 key input: AUX2 output
DME2 video input: AUX4 output
DME2 key input: AUX5 output
Note that for a DME external video signal, you can select
any of AUX1 to AUX14 on the DME. Connect to the
selected AUX bus.
Making Switcher Processor GPI
Input Settings
1
In the Switcher >Device Interface menu, press [GPI
Input].
The GPI Input menu appears.
2
Using any of the following methods, select the
settings.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knobs.
Knob
Parameter
Adjustment
Setting values
1
Port
Port selection
1 to 8
2
No
Selection of
number for
action to be
assigned
1 to 8
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge): Apply the trigger on a rising
edge of an input pulse.
(Falling Edge): Apply the trigger on a falling
edge of an input pulse.
(Any Edge): Apply the trigger on a change in
the polarity of the input signal.
(Level): Carry out the specified operation when
the input is low or high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1 to M/E-5, P/P: Set the action for one of the
banks.
Common/Setup: Set an action for something other
than the above, or a setup action.
5
Using any of the following methods, select the action
to be set.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knobs.
Knob
Parameter
Adjustment
Setting values
3
Action
Action selection
1 to maximum
value
a)
4
Reg No
Register number
1 to 4
b)
1 to 99
c)
a)
As for the setting values, see “Selectable actions for various trigger
types” (page 631).
b)
When knob 3 selection is “Key Snapshot”
c)
When knob 3 selection is “Snapshot” or “Effect”
6
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
Selectable actions for various trigger types
When the trigger type is other than “Level”
In M/E-x, the x is the M/E bank number (1 to 5); in
DSKx the x is the DSK number (1 to 8); in Keyx the x is
the key number (1 to 8).
-
When Target is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, SS ? Recall, Keyx SS ? Recall,
Effect ? Recall, Effect ? Recall & Run, KF Run, KF
Stop, KF Rewind, KF Rev Run, No Action
-
When Target is P/P: Cut, Auto Trans, DSKx Cut,
DSKx Auto Trans, FTB Cut, FTB Auto Trans, SS ?
Recall, DSKx SS ? Recall, Effect ? Recall, Effect ?
Recall & Run, KF Run, KF Stop, KF Rewind, KF Rev
Run, No Action
-
When Target is Common/Setup: FM Src1 Field
Freeze, FM Src1 Frame Freeze, FM Src2 Field Freeze,
FM Src2 Frame Freeze, FM Src1 Freeze Off, FM Src2
Freeze Off, FM Src1 Clip Record, FM Src1 Clip Stop,
FM Src2 Clip Record, FM Src2 Clip Stop, FM1 to
FM8 Clip Cueup, FM1 to FM8 Clip Play, FM1 to FM8
Clip Stop, User1 to 8 SS ? Recall, User1 to 8 EFF ?
Recall, User1 to 8 EFF ? Recall & Run, User1 to 8 KF
Run, User1 to 8 KF Stop, User1 to 8 KF Rewind,
User1 to 8 KF Reverse Run, No Action
When the trigger type is Level”
In M/E-x, the x is the M/E bank number (1 to 5).
-
When Target is M/E-x or P/P: Aspect, Bkgd A Side
Flags, Bkgd B Side Flags, No Action
-
When Target is Common/Setup: Format, Aspect,
Level Enable, No Action
Notes
“Level Enable” is a function that determines whether
GPI inputs are enabled (“Enable”) or disabled
(“Disable”) for the “Aspect” and “Format actions that
can be used when the trigger type is Level. When Level
Enable is used, if the input is “Disable” then it is not
possible to switch “Aspect” or “Format” by GPI input.
If a GPI to switch “Aspect or Format” occurs when
powering the system off, the action triggered by the GPI

Table of Contents