EasyManua.ls Logo

Sony MVS-8000X SystemMVS-7000X System - Symbols and Parameters

Sony MVS-8000X SystemMVS-7000X System
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USO RESTRITO
668
Macro File Editing Rules
Appendix
(Volume
2)
Event
Symbol
Using Continue
Record with device
DeviceRecord
Yes
AUX mix transition on/off
AuxMix
No
a) For details of pause events, see “Macro Execution” (page 498).
Symbols and Parameters
n: indicates a numeral 0 to 9. x: indicates an alphanumeric character.
Symbol
Parameter name
Arguments
Description
MEXpt
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
MEBus?
A, B, Key1 to Key8,
Key1Source to
Key8Source, Utility1,
Utility2, DMEExternalVideo
Applicable bus
Xpt?
1 to 300
Main table cross-point button number
set in the Xpt Assign menu
VideoKey?
Video, Key
Signal type selected on the applicable
bus (video signal or key signal)
AuxXpt
AuxBus?
EditPreview, AUX1 to
AUX48, FrameMemory1,
FrameMemory2,
DME1Video to
DME8Video, DME1Key to
DME8Key, DME1Video2nd
to DME8Video2nd (a),
DME1Key2nd to
DME8Key2nd (b),
DMEUtility1, DMEUtility2,
CCR1, CCR2
Applicable AUX bus
(a): DMEnVideo2nd= Bus for selecting
back video signal of DMEn channel
(n=1 to 8),
(b): DMEnKey2nd= Bus for selecting
back key signal of DMEn channel (n=1
to 8)
Xpt?
1 to 300
Cross-point button number in the main
table set in the Xpt Assign menu
VideoKey?
Video, Key
Type of signal (video signal or key
signal) to be selected on the applicable
bus
MEAutoTransition
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
Time?
Current (a), 0 to 999
Transition rate (number of frames)
(a): Mode in which the current value set
on the transition control block is used
ABusXpt?
Current (a), 1 to 300
A bus or B bus cross-point button
number. Use the button number of the
main table set in the Xpt Assign menu.
(a): Mode in which the cross-point
number set for the current A bus or B
bus is used
BBusXpt?
Current (a), 1 to 300
MECut
ME?
ME1 to ME5, PP
Control blocks on the applicable bank

Table of Contents

Related product manuals