M/E Configuration Switching
Knob
Parameter
Adjustment
Setting values
1
1ch
Disparity
Adjust the
degree of depth
perception for
channel 1
8.00 to 8.00
2
2ch
Disparity
Adjust the
degree of depth
perception for
channel 2
8.00 to 8.00
Chapter
10
Special
Functions
Video Creation in 3D Mode
Adjusting the parallax using the DME
By adjusting the parallax (see page 260), you can control
the degree of depth perception.
1
Display the Global Effect >Ch1 to Ch4 >3D Mode
menu.
2
To adjust the parallax, press [Parallax].
3
Turn the knobs to adjust the following parameters.
Knob
Parameter
Adjustment
Setting values
1
1ch
Parallax
Adjust the
parallax for
channel 1
0.00 to 8.00
2
2ch
Parallax
Adjust the
parallax for
channel 2
0.00 to 8.00
Notes
If the position of an image in three-dimensional space
is in the plane of the monitor screen, adjusting the
parallax does not change the 3D effect. In this case,
adjust the parameters in the local coordinate space so
that the image is either in front of or behind the plane
of the screen before adjusting the parallax.
4
To adjust the perspective without changing a size or
shape, press [Disparity].
5
Turn the knobs to adjust the following parameters.
M/E Configuration
Switching
On the MVS-7000X, a single mix/effect board MKS-
7210X can be shared among a number of M/E banks.
On up to a maximum of three boards, 2M/E mode, 3M/E
mode, or 4M/E mode can be assigned. It is also possible to
set no assignment.
Using this function, you can select the M/E configuration
of the whole switcher from the following.
Number of
assigned M/Es
Number of keys available on a single
M/E
1
8
2
4
3
M/E-1, M/E-2
2
PGM/PST
4
4
2
In this manual, using a single MKS-7210X board is
referred to as 1M/E mode, 2M/E mode, 3M/E mode, or
4M/E mode depending on the maximum number of M/Es
on which the board is used.
Notes
When three or four M/Es are assigned to a board, the
other two boards are automatically indicated as
“Disable”, and assignment is no longer possible.
When the signal format is 1080P, each MKS-7210X
board can only be used on a single 1M/E and the number
of available keys is 4.
In 2M/E mode, DME selection on a single M/E is as
follows.
-
Two places when the dedicated interface is used.
-
One place when the SDI interface is used.
Setting the number of M/Es for each board
Use the following procedure.
1 Display the Engineering Setup >System >Install/Unit
Config >Unit Config >M/E Split menu.