Applying Special Effects (Nonlinear Effect Settings)
Knob
Parameter
Adjustment
Setting values
1
Rotation
Number of
rotations of
the blocks
8.000 to +8.000
2
Perspective
Degree of
randomness in
distance
moved by
each block
0.000 to 100.000
Knob
Parameter
Adjustment
Setting values
1
Transition
Degree of
transition
0.000 to 100.000
2
Random
Degree of
randomness in
distance
moved by
each block
100.000 to
+100.000
3
Angle
Direction of
movement
8.000 to +8.000
Knob
Parameter
Adjustment
Setting values
1
Width
Width of
partition
0.000 to 100.000
2
Random
Degree of
randomness in
partition width
0.000 to 100.000
3
Angle
Partition angle
8.000 to +8.000
Knob
Parameter
Adjustment
Setting values
1
H
Horizontal
center
position
8.000 to +8.000
a)
32.000 to
+32.000
b)
2
V
Vertical
center
position
6.000 to +6.000
a)
18.000 to
+18.000
b)
Chapter
11
DME
Operations
To apply the Broken Glass effect
Display the Broken Glass menu.
The functions of the knobs in the Broken Glass menu are
the same as those of the Rings menu (see page 319), with
the exception of [Direction].
To fix the direction in which shards scatter
Press [Direction], turning it on.
To apply the Blind effect
With the Blind menu displayed, use the following
procedure.
1
In the <Mode> group, select [Bar] or [Wedge].
2
To make transition settings, press [Transition] and set
the following parameters.
Flying Bar Settings
You can set the degree of transition, the degree of
randomness in the distance moved by each block, the
direction of movement, the width of the partitions, the
degree of randomness in partition width, the partition
angle, and other parameters.
To apply the Flying Bar effect
With the Flying Bars menu displayed, use the following
procedure.
1
To make transition settings, press [Transition] and set
the following parameters.
2
To set the partition method, press [Partition] and set
the following parameters.
3
To set the partition method, press [Partition] and set
the following parameters.
When Bar was selected in step 1
Knob
Parameter
Adjustment
Setting values
1
Width
Width of
partition
0.000 to 100.000
2
Offset
Degree of
randomness in
partition width
5.000 to
+5.000
a)
20.000 to
20.000
b)
3
Angle
Starting angle
of effect
8.000 to +8.000
a)
Setting for SD 4:3, SD 16:9
b)
Setting for HD 4:3, HD 16:9
When Wedge was selected in step 1
Knob
Parameter
Adjustment
Setting values
4
No
Width of
blocks
0.000 to 100.000
5
Phase
Partition
position
8.000 to +8.000
To set the wedge center position
When Wedge is selected in the <Mode> group, you can set
the wedge center position.
1
Press [Position].
2
Set the following parameters.
Blind Settings
There are two modes: Bar and Wedge. You can set the
number of rotations by blocks, the perspective, the width
and position of blocks, the direction, the center position,
and other parameters.

Table of Contents