Applying Special Effects (Effects on the Overall Video Signal)
Knob
Parameter
Adjustment
Settings values
1
H
Horizontal
defocusing of
key signal
0.00 to 100.00
2
V
Vertical
defocusing of
key signal
0.00 to 100.00
3
All
Horizontal
and vertical
defocusing of
key signal
H value shown
Knob
Parameter
Adjustment
Setting values
1
V/K H
Horizontal
defocusing of
video and
key signals
Video H value
shown
2
V/K V
Vertical
defocusing of
video and
key signals
Video V value
shown
3
V/K All
Horizontal
and vertical
defocusing of
video and
key signals
Video H value
shown
4
Video All
Horizontal
and vertical
defocusing of
video signal
Video H value
shown
5
Key All
Horizontal
and vertical
defocusing of
key signal
Key H value shown
Knob
Parameter
Adjustment
Settings values
1
Video H
Horizontal
defocusing of
video signal
0.00 to 100.00
2
Video V
Vertical
defocusing of
video signal
0.00 to 100.00
3
Key H
Horizontal
defocusing of
key signal
0.00 to 100.00
4
Key V
Vertical
defocusing of
key signal
0.00 to 100.00
Knob
Parameter
Adjustment
Setting values
1
H
Horizontal
defocusing of
video signal
0.00 to 100.00
2
V
Vertical
defocusing of
video signal
0.00 to 100.00
3
All
Horizontal
and vertical
defocusing of
video signal
H value shown
Chapter
11
DME
Operations
When Video/Key is selected (with SDI-interfaced
DME)
When Key is selected (with SDI-interfaced DME)
Parameter group [1/2]
5
To cancel black level leaking that can occur at the edge
of the screen when the Defocus effect is enabled, press
[Clean Defocus], turning it on.
Masking the Defocus effect with a selected
pattern
Press [Mask] to display the Mask menu, and set the pattern
type and modifiers (see page 310).
Parameter group [2/2]
When Video is selected
.
Blur Settings
Applying the Blur effect
1
In the DME menu, select VF2 ‘Video Modify’ and
HF1 ‘Defocus/Blur.’
The Defocus/Blur menu appears.
2
Press [Blur], turning it on.
Notes
On the MVE-8000A, the Glow and Blur effects cannot
be enabled at the same time. The effect which was
turned on most recently is enabled.
3
When the DME is connected through an SDI interface,
in the <Blur Mode> group, select the signal to which
you want apply the Blur effect.
Video/Key: Video signal and key signal
Video: Video signal only
Key: Key signal only
4
Set the parameters.
When the DME dedicated interface is used
Knob
Parameter
Adjustment
Setting values
1
H
Horizontal
defocusing of
video and
key signals
0.00 to 100.00