Signal Input Settings (Input Menu) 613
Knob
Parameter
Adjustment
Setting values
1
Video Gain
Video signal gain
200.00 to
+200.00
2
Y Gain
Y signal gain
200.00 to
+200.00
3
C Gain
Chrominance
signal gain
200.00 to
+200.00
4
Hue Delay
Hue delay
180.00 to
+180.00
5
Black Level
Black level
7.31 to
+109.59
Chapter
20
Switcher
Setup
(Switcher)
Signal Input Settings
(Input Menu)
For setup relating to signal inputs, use the Switcher >Input
menu.
To display the Input menu
In the Engineering Setup menu, select VF3 ‘Switcher’ and
HF2 ‘Input.’
The status area shows source numbers and source names
and through mode on/off setting.
The following functions are available here.
Through Mode: Set the through mode for input. You
can set this independently for each primary input or
premium input.
Video Process: Switch video processing on or off for
each input signal, and adjust the brightness, hue and so
forth.
Matte Illeg. Color Limit: Switch the illegal limiter on
or off for the signal generated by the switcher internal
matte generator.
FC Input Select: Select the primary input to be used in
the format converter (MVS-7000X only).
FC Adjust: Select the conversion (up-conversion,
cross-conversion, or down-conversion) when the format
converter is applied to an input.
Making Through Mode Settings
Notes
For the format converter dedicated inputs in the MVS-
8000X, you cannot set through mode.
For the MVS-7000X, through mode is enabled for the
input signals which have been converted in the format
converter.
1
In the Switcher >Input menu, select the input signal to
which the settings apply.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knob.
Knob
Parameter
Adjustment
Setting values
1
Src No
Input signal
selection
1 to maximum
value
a) b)
a)
The following values apply to the MVS-8000X.
For primary inputs: 1 to 144
For premium inputs: 145 to 164 ((PREM1) to (PREM20) indicated
after the number)
b)
The values from 1 to 80 apply to the MVS-7000X.
The selected input signal appears in reverse video.
2
To enable through mode, press [Through Mode],
turning it on.
Making Video Process Settings
1
In the Switcher >Input menu, press [Video Process].
The Video Process menu appears.
The status area shows the source number, source
name, and video process adjustment settings.
2
Using any of the following methods, select the input
signal to which the settings apply.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video
cursor.
Turn the knob.
Parameter group [2/2]
Knob
Parameter
Adjustment
Setting values
1
Src No
Input signal
selection
1 to maximum
value
a) b)
a)
The following values apply to the MVS-8000X.
For primary inputs: 1 to 144
For premium inputs: 145 to 164 ((PREM1) to (PREM20) indicated
after the number)
For format converter dedicated inputs: 165 to 180 ((FC1) to (FC16)
indicated after the number)
b)
The values from 1 to 80 apply to the MVS-7000X.
For primary inputs: 1 to 80
Input signals which have been converted in the format converter: 81
to 88
3
Press [Video Process], turning it on.
4
Adjust the following parameters.
Parameter group [1/2]
To set the parameter settings to their defaults, press
[Unity].

Table of Contents