Chapter
10
Special
Functions
For details, see “Assigning Output Signals” in Chapter 20
(Volume 2).
Assigning main and/or sub to switcher
banks
For each switcher bank for which Multi Program 2 mode
is selected, set whether this is main dedicated, sub
dedicated, or main and sub shared.
To assign main and sub to a single switcher bank
1
In the Engineering Setup >Panel >Config >MP2 Main/
Sub Assign menu, select the switcher bank.
2
In the <Main/Sub Assign> group, select [Main&Sub].
Main: use for main operations.
Sub: use for sub operations.
Main&Sub: use for both main and sub operations.
When “Main&Sub” is selected, it is necessary to
assign [MAIN] and [SUB] delegation buttons to the
control panel buttons.
To assign main and sub to two consecutive
switcher banks
For example, to assign the first row (first switcher bank) to
M/E-1 main, and the second row (second switcher bank) to
M/E-1 sub, use the following procedure.
1
In the status area of the Engineering Setup >Panel
>Config >MP2 Main/Sub Assign menu, select 1st
Row (M/E-1), then press [Main] in the <Main/Sub
Assign> group.
2
Press [Dual M/E Assign] to assign M/E to two banks.
In this state, both 1st Row and 2nd Row are set to
main.
3
Set 2nd Row to [Sub].
This cancels the shift/non-shift assignment for dual M/
E in standard mode.
Notes
It is not possible to assign the combinations of Main with
Main&Sub, or Sub with Main&Sub.
Assigning the [MAIN] and [SUB]
delegation buttons to buttons on the
control panel
To assign the Main/Sub switching function to
buttons in the transition control block
This applies to the standard type and compact type
transition control block, and the CCP-6224/6324 control
panel.
For details of the transition control block, see “Transition
Control Block (Standard Type)” (page 37) and
“Transition Control Block (Compact Type)” (page 68).
For details of the control panel, see “CCP-6224 2M/E
Control Panel” (page 71), and “CCP-6324 3M/E Control
Panel” (page 71).
1
In the Engineering Setup >Panel >Config menu, press
[Program Button].
The Program Button menu appears.
2
Press [Transition Module1].
The Transition Module1 menu appears.
3
Select the switcher bank in the <Bank Select> group.
The buttons in the transition control block on the left
appear in the currently assigned state.
4
Press the button whose assignment you wish to
change.
The button you press appears in reverse video.
5
From the list on the right, select [MAIN], and press
[Set].
The indication on the button changes according to the
selection.
6
Repeat Step 4 and 5 to assign [SUB].
To assign to macro buttons in the cross-point
control block
For details, see “Cross-Point Control Block” (page 32).
1
In the Engineering Setup >Panel >Config menu, press
[Program Button].
The Program Button menu appears.
2
Press [Xpt Module].
The Xpt Module menu appears.
3
Select the switcher bank, then in the <PRE MCRO/
POST MCRO> group, press [Main Sub].
You can now use the [PRE MCRO] button as [MAIN],
and the [POST MCRO] button as [SUB].
To assign macro operations to different buttons
If in the above operation you assigned a Multi Program 2
function to the macro buttons, you can assign the PRE
MCRO and POST MCRO functions to different buttons.