EasyManua.ls Logo

Sony MVS-8000X SystemMVS-7000X System - Page 670

Sony MVS-8000X SystemMVS-7000X System
706 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USO RESTRITO
670
Macro File Editing Rules
Appendix
(Volume
2)
Symbol
Parameter name
Arguments
Description
Snapshot
Region?
ME1 to ME5, PP, User1 to
User8, DME1 to DME8,
Router
Applicable region
Register?
1 to 99
Applicable register number
Attribute?
Off, Dissolve,
AutoTransition,
Dissolve&AutoTransition
Applicable snapshot attributes
Time?
Current (a), 0 to 999
Duration of effect dissolve (number of
frames)
(a): Mode in which the currently set
value is used
KeySnapshot
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
Key?
Key1 to Key8
Applicable key
Register?
1 to 4
Applicable register number
WipeSnapshot
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
Register?
1 to 10
Applicable register number
DMEWipeSnapshot
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
Register?
1 to 10
Applicable register number
TimelineRecall
Region?
ME1 to ME5, PP, User1 to
User8, DME1 to DME8,
PBus, Device1 to
Device12, GPI
Applicable region
Register?
1 to 399
Applicable register number
TimelineRun
Region?
ME1 to ME5, PP, User1 to
User8, DME1 to DME8,
PBus, Device1 to
Device12, GPI, Current (a)
Applicable region
(a): Mode in which operation takes
place in the region currently specified
in the numeric keypad control block
TimelineRewind
Region?
ME1 to ME5, PP, User1 to
User8, DME1 to DME8,
PBus, Device1 to
Device12, GPI, Current (a)
Applicable region
(a): Mode in which operation takes
place in the region currently specified
in the numeric keypad control block
TimelineFF
Region?
ME1 to ME5, PP, User1 to
User8, DME1 to DME8,
PBus, Device1 to
Device12, GPI, Current (a)
Applicable region
(a): Mode in which operation takes
place in the region currently specified
in the numeric keypad control block
Shotbox
Register?
1 to 99
Applicable register number
Pause
Time?
0 to 999
Time for which macro is paused
(number of frames)
StartTc
Device?
1 to 12,
FrameMemory1Clip to
FrameMemory8Clip
Applicable device
MasterSnapshot
Register?
1 to 99
Applicable register number
MasterTimelineRecall
Register?
1 to 99
Applicable register number
RouterXpt
DestinationButton?
1 to 128
Router cross-point button
Source?
1 to 1024
Router source number
Level?
1 to 8
Router level selection
PatternLimit
ME?
ME1 to ME5, PP
Control blocks on the applicable bank
Status?
ToOn (a),
ToOff (b),
Any (c)
Pattern limit status
(a): Pattern limit applies
(b): Pattern limit does not apply
(c): The pattern limit status always
changes

Table of Contents

Related product manuals