Data Saved by [Setup Define] and [Initial Status Define] 
 
Engineering Setup >Panel >Prefs/Utility >Utility 
Module Assign 
All data relating to function assignment to utility/ 
shotbox control block 
Engineering Setup >Panel >Prefs/Utility >Key 2/4 
Bus Button Assign 
All data relating to utility/shotbox assignment to 
cross-point buttons in the key 2 row 
Engineering Setup >Panel >Device Interface 
All data relating to Device Interface menu 
Engineering Setup >Panel >Device Interface >GPI 
Input 
All data relating to GPI Input menu 
Engineering Setup >Panel >Device Interface >GPI 
Output 
All data relating to GPI Output menu 
Engineering Setup >Panel >Device Interface >DCU 
Serial Port/MPE Assign 
All data relating to DCU Serial Port/MPE Assign 
menu 
Engineering Setup >Panel >Operation 
All data relating to Operation menu 
Engineering Setup >Panel >Operation >Effect Mode 
All data relating to Effect Mode menu (excluding 
[Default KF Duration] setting values) 
Engineering Setup >Panel >Operation >Flexi Pad 
Mode 
All data relating to Flexi Pad Mode menu 
Engineering Setup >Panel >Operation >Custom 
Button 
All data relating to Custom Button menu 
Engineering Setup >Panel >Operation >Sensitivity 
All data relating to Sensitivity menu 
Engineering Setup >Panel >Operation >Macro 
All data relating to Macro menu 
Engineering Setup >Panel >Operation >ButtonTally 
All data relating to ButtonTally menu 
Engineering Setup >Panel >Operation >Key Row 
Operation 
All data relating to Key Row Operation menu 
Engineering Setup >Panel >Maintenance 
•  Setting data for the following buttons: 
-  [Screen Saver] 
-  [LCD Brightness] 
-  [LED Brightness] 
-  [Switch Brightness] 
-  [Touch Beep] 
•  Setting data for Initial Menu 
Engineering Setup >Router/Tally 
All data relating to router interface and tally interface 
Data of Color Palette window 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
Included in Switcher Setup 
 
All data relating to Safe Title menu 
Engineering Setup >Panel >Xpt Assign >Main, V/K 
Pair Assign 
Cross-point assignment settings (excluding <Xpt 
Shift Mode> and <Display Shift Mode> groups) 
Engineering Setup >Panel >Xpt Assign >Src Name/ 
LCD Color 
•  Names of source signals 
•  Color of source name display for each source 
signal 
Engineering Setup >Panel >Operation >Effect Mode 
Setting of [Default KF Duration] for switcher 
keyframes 
7331 
7331.1 
7331.2 
7331.3 
•  Engineering Setup >Switcher >Config 
•  Engineering Setup >Switcher >Config >M/E 
Output Assign 
•  Engineering Setup >Switcher >Config >PGM 
Config 
•  Engineering Setup >Switcher >Config >K-PVW 
Config 
•  All data relating to Config menu 
•  All data relating to M/E Output Assign menu 
•  All data relating to PGM Config menu 
•  All data relating to K-PVW Config menu