6 – 109
Chapter 6 General
Tray1 Feed SOLENOID (Auto)
NOTE: This procedure is for the technical staff.
When performing operation for five minutes or longer with the front cover
open, remove the PHD ASSY, and cover the drum to avoid exposure to light.
1) Remove the COVER SIDE L.
2) Power on the printer, and enter the Diag Mode.
3) Cheat the Safety Interlock System.
4) Execute the Tray1 Feed SOLENOID (Auto).
5) Check that the Feed Solenoid movement.
6) Press the "STOP" key to stop the test.
7) Remove the cheater.
8) Replace the COVER SIDE L.
Tray2 Feed SOLENOID (Auto)
NOTE: This procedure is for the technical staff.
1) Remove the COVER REAR OPT and COVER SIDE L OPT.
2) Power on the printer, and enter the Diag Mode.
3) Execute the Tray2 Feed SOLENOID (Auto).
4) Check that the Feed Solenoid movement.
5) Press the "STOP" key to stop the test.
6) Replace the COVER REAR OPT and COVER SIDE L OPT.
Motor/Clutch/Solenoid Name
(Diag. Code)
Check procedure
Rio02018KA
Cassette1 Feed Solenoid
MiA02026GA
Tray 2 Feed Solenoid