Operation Manual – HWPing
H3C S3100 Series Ethernet Switches Chapter 1 HWPing Configuration
1-13
Operation Command Description
Configure the source port
source-port port-number
Optional
By default, no source port
is configured.
Configure the number of
probes per test
count times
Optional
By default, each test
makes one probe.
Configure the maximum
number of history records
that can be saved
history-records number
Optional
By default, the maximum
number is 50.
Configure the packet size
datasize size
Optional
By default, the packet size
is 68 bytes.
Configure the automatic
test interval
frequency interval
Optional
By default, the automatic
test interval is zero
seconds, indicating no
automatic test will be
made.
Configure the probe
timeout time
timeout time
Optional
By default, a probe times
out in three seconds.
Configure the type of
service
tos value
Optional
By default, the service
type is zero.
Configure the number of
test packets that will be
sent in each jitter probe
jitter-packetnum number
Optional
By default, each jitter
probe will send 10
packets.
Configure the interval to
send test packets in the
jitter test
jitter-interval interval
Optional
By default, the interval is
20 milliseconds.
Start the test
test-enable
Required
Display test results
display hwping results
[ admin-name
operation-tag ]
Required
You can execute the
command in any view.
6) Configuring SNMP test on HWPing client