Chapter 4 ’Servicing’ — Hardware Delivery
438 Electra VS
-
Version 05.10
User Manual - Rev. A
1.
Install the HP Virtual Connect Support Utility Set (VCSU) available on
the DVD-ROM in the FLEX10 directory on your remote desktop.
2.
Open a windows console.
3.
Go to the VCSU directory
Type
cd C:\Program Files\Hewlett-Packard Company\Virtual
Connect Support Utility
4.
Type the following command
:
vcsu.exe -a update -i XXX.XXX.XXX.XXX -u Administrator -p
pwdOA -vcu Administrator -vcp pwdFlex10 -l "C:\Integrati
on-VS7000\vcfwall370.bin"
XXX.XXX.XXX.XXX
: Target OA IP address
pwdOA
: OA password
pwdFlex10
: Flex10 password
C:\Integration-VS7000\vcfwall370.bin
: path of the Flex10
firmware upgrade
5.
Type
Y
to confirm the operation when requested.
The upgrade may take up to 1 hour for the upgrade of the two Flex 10.
6.
Check that all the modules have successfully been updated in the
windows console and again perform a Flex10 firmware version check
through the OA.
Upgrade trace example:
-------------------------------------------------------------------------------
HP BladeSystem c-Class Virtual Connect Support Utility
Version 1.5.2 (Build 173)
Build Date: Jan 6 2011 11:26:43
Copyright (C) 2007-2010 Hewlett-Packard Development Company, L.P.
All Rights Reserved
-------------------------------------------------------------------------------
The following modules will be updated:
==============================================================================
Enclosure Bay Module Current Version New Version
==============================================================================
CZ3126JYDP 1 HP VC Flex-10 3.18 3.30
Enet Module 2011-04-01T22:57:39Z 2011-08-16T02:29:46Z
------------------------------------------------------------------------------
CZ3126JYDP 2 HP VC Flex-10 3.18 3.30
Enet Module 2011-04-01T22:57:39Z 2011-08-16T02:29:46Z
------------------------------------------------------------------------------
During the update process, modules being updated will be temporarily unavailable. In addition, the
update process should NOT be interrupted by removing or resetting modules, or by closing the
application. Interrupting the update or the modules being updated may cause the modules to not be
updated properly.
Please verify the above report before continuing.
Would you like to continue with this update? [YES/NO]: YES
The following modules were updated successfully:
=======================================================================
Enclosure Bay Module New Version
=======================================================================
CZ3126JYDP 1 HP VC Flex-10 Enet Module 3.51 2011-08-16T02:29:46Z
CZ3126JYDP 2 HP VC Flex-10 Enet Module 3.51 2011-08-16T02:29:46Z