Chapter 5 ’Troubleshooting’ — Frequently Asked Questions
Electra VS
-
Version 05.10 455
User Manual - Rev. A
HKLM\SYSTEM\CurrentControlSet\Control\Session
Manager\Memory Management\LargeSystemCache = 1
This key tells Windows to set aside enough system cache for
sharing large files.
HKLM\SYSTEM\CurrentControlSet\Services\LanmanServer\P
arameters\Size = 3
This value tells Windows to prioritize file sharing over reducing
memory usage.
Reboot your Windows server after key modification.
The SNMP agent does not work. What should I do?
In the
Setup
tab,
SNMP
category, check that the Read and Read/Write
communities are entered.
It takes a long time to launch the GUI. Why?
Before launching the signed GUI application, the client station checks
through Java (starting in version 1.7.xx) that the related certificate has not
been revoked by the issuing authority.
If the Java setting does not allow internet access, the certificate
revocation check attempt will fail after about 1 minute. The starting applet
will be run but only after this time.
You have two solutions to reduce this startup time:
Solution 1
: Allow internet access from the client station so that the
certification authority revocation check request can run normally. Java
should be configured with the proxy settings.
Solution 2
: Disable certification authority revocation checking in Java.
Java should be set to disable this check.
Procedure
1.
Run the Java Control Panel as follows:
Run the Windows
Start
menu
Click
Programs
Select the
Java
directory
Click
Configure Java
to run the Java Control Panel