EasyManua.ls Logo

Harmonic ELECTRA VS - Using VOS Flex Nodebench

Harmonic ELECTRA VS
604 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 ’Tools’ — NodeBench
Electra VS
-
Version 05.10 467
User Manual - Rev. A
-
Select Run Electra VS (for evaluation using NodeBench
tool)
b.
Configure the management IP address
-
Connect in Guest mode (User =
THVNguest
Pwd =
THVNpwd0
)
-
Execute the following command:
setIP -l bond<> -l lannumber -a @IP/mask <-t if
tagged> -g @IPgateway
: configure the management IP
address, after configuration you can access the Web
interface using the address configured
Example :
setIP -a 198.18.76.244/21 -g 198.18.64.1
-l 3064 -d eth0
The management IP address will be set to 198.18.76.244 in
LAN 3064 in the first network interface.
c.
Connect a PC to the configured management interface
You can now connect to the Electra VS Web Interface using the
PC.
Refer to
Chapter 2 ’Installation and Startup’
, section
Accessing the Web Interface for the First Time
on page 63.
Using VOS Flex NodeBench
VOS Flex NodeBench analyzes can be executed
On a hardware platform not integrated in a Electra VS, in order to
assess the level of performances which can be expected from the
target servers and perform accurate simulation.
On a new hardware platform added in a already existing Electra VS.
On a hardware platform already integrated in a Electra VS, in order to
check if its real processing capacity corresponds to the configured
one.
To launch NodeBench analyze, proceed as follows:
1.
Select the
Hardware
tab.
2.
Go to the
Nodes
category.
3.
Select the
Node
to analyze.
Note: If jobs are running on the target node the NodeBench analyze
will be refused. If it is the case you can stop the job running on the
node or reboot it to force them to be restart on another node if
available.

Table of Contents