Appendix E ’Logs’ — List of Logs
Electra VS
-
Version 05.10 567
User Manual - Rev. A
55 Alarm Undefined (Major) File error: cannot create output file %s on folder %s
56 Event Major Unreachable network storage: %s
57 Alarm Major Input overflow
58 Alarm Minor No AFD in signal
59 Alarm Minor No WSS in signal
60 Alarm Minor Configuration inconsistency: PCR PID is not defined for
output program %d
61 Alarm Major Link down: interface %d
62 Alarm Major Configuration inconsistency: PMT PID %d is not the
configured one (%d)
63 Alarm Warning Link down: %s NIC of interface %d
64 Event Undefined (Info) Job completed
65 Alarm Critical Configuration inconsistency: audio bitrate (%d bps) should
be in the range [%d-%d] for %s encoding
66 Alarm Warning Job modification is waiting: %s
67 Alarm Major No component: Track Id %d missing
68 Alarm Major Component processing problem: unsupported format (%s)
69 Alarm Minor Fallback mode: component %s uses fallback bitrate (%d
bps)
70 Alarm Minor Configuration inconsistency: configured component
bitrate range [%d-%d] should be in the range [%d-%d] for
PID %d
71 Alarm Warning Software error: database incorrect version (%s)
72 Alarm Warning Software error: current software version integrity is not
verified (%s)
73 Alarm Major Output overflow: %s
74 Alarm Undefined (Info) Version activation installation of version %s in progress
75 Alarm Undefined (Info) Version activation job upgrade in progress
76 Alarm Critical Database inconsistency: please contact
support@thomson-networks.com
77 Event Major Job restarted: database inconsistency detected and
corrected
78 Event Critical Database inconsistency: data (setup, workflows, jobs, logs)
from %s (UTC) are restored
79 Alarm Warning Signaling information not present: no Closed Caption
descriptor in PMT of program number %d
80 Alarm Warning Software error: %s
81 Event Undefined (Info) Master change: %s