EasyManua.ls Logo

MA lighting dot2 - Page 33

MA lighting dot2
614 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2018 MA Lighting Technology GmbH - Dachdeckerstr. 16 - 97297 Waldbüttelbrunn - Germany
Phone +49 5251 688865-27 - support@ma-dot2.com - www.malighting.com
1
This is the final result:
Cue
number
Fixture 1
Dim
Fixture 1
Position
1 100 Singer
2 0 Singer
3 100 Drummer
4 0 Drummer
5 0 Drummer
6 100 Singer
This is the principle behind Tracking Shield:
The system looks for dimmer values that change from 0 to above 0 for each single fixture. If there's a change in
the dimmer (from 0 to a value above), then it stores the tracked values before creating the new values in the
previous cues, thus preventing the cue output from changing because of the tracking.
The dimmer value in cue 5 is a tracked value, even though we store both 4 and 5 as Cue Only because of a
function called AutoUnblock. It's the same mechanism that made the dimmer in cue 6 a tracked value after we
stored cue 3. AutoUnblock will automatically remove unnecessary stored values after each store operation.
33 of 614
dot2 User Manual - What are...
Version 1.5 2018-11-29
English

Table of Contents

Other manuals for MA lighting dot2

Related product manuals