System SP1-xxx
D086/D087 3-36 SM Appendix
135 Long:Fusing:Thick 1:Low *ENG
[–4 to 4 / 1.7 / 0.01 %/step]
136 Long:Fusing:Thick 2:Low *ENG
[–4 to 4 / 1.7 / 0.01 %/step]
137 Long:Fusing:Thick 3:Low *ENG
[–4 to 4 / 1.7 / 0.01 %/step]
1902 [Amplitude Control]
001 Execute - Execute drum phase adjustment.
002 Result *ENG
[0 to 3 / 0 / 1]
Displays the result of drum phase
adjustment.
0: Successfully done
2: Sampling failure
3: Insufficient detection number
003 Auto Execution *ENG
[0 or 1 / 1 / -]
Turns the automatic drum phase
adjustment on or off.
0: Off, 1: On
1907
[Paper Feed Timing Adj.] DFU
002 Feed Solenoid ON: Plain *ENG
[35 to 85 / 60 / 5 %/step]
003 Feed Clutch OFF: Plain *ENG
[–10 to 10 / 0 / 1 mm/step]
004 Feed Clutch ON: Plain *ENG
005 Inverter Stop Position *ENG
006 Reverse Stop Position *ENG
007 Re-Feed Stop Position S Size *ENG
008 By-pass Solenoid OFF *ENG
[0 to 40 / 0 / 1 mm/step]