System SP1-xxx
SM Appendix 3-39 D086/D087
Appendix:
SP Mode
Tables
1952 [Fan Control Off Mode Time Set]
001 - *ENG
[0 to 60 / 10 / 1 min./step]
1953 [Extra Fan Control]
001
Extra Fan Cooling State *ENG
[0 or 1 / 0 / 1 /step]
0: Off, 1: On
Displays the extra fan cooling is On or Off.
002
Extra Fan Cooling: Time:
Threshold
*ENG
[0 to 180 / C2.5a: 110, C2.5b: 100 / 1
min./step]
Specifies the judgement time for entering the extra fan rotation mode.
003
Extra Fan Cooling: Rotat:
Threshold
*ENG
[0 to 999999999 / 0 / 1 mm/step]
Specifies the threshold rotation of the black development unit for entering the
extra fan rotation mode.
004
Extra Fan Cooling: Start
Date
*ENG
Displays the execution time and date of
the extra fan cooling.
005
Extra Fan Cooling Time *ENG
[0 to 120 / 30 / 0.1 min./step:
Specifies the execution time for the extra fan cooling.
1954
[Extra Fan Control]
Specifies the execution time of the extra fan rotaion mode for each fan motor.
002
Fan Cooling Time:Fusing
Exit Fan:Initial
*ENG
[0 to 120 / 0 / 0.1 min./step]
006
Fan Cooling Time:Main
Suction Fan:Initial
*ENG
[0 to 120 / 0 / 0.1 min./step]
007
Fan Cooling Time:Paper
Exit Fan:Initial
*ENG
[0 to 120 / 0 / 0.1 min./step]
008 Fan Cooling Time:PSU *ENG
[0 to 120 / 0 / 0.1 min./step]