Service RAM Addresses
D393 164 SM
6BEC01(H) – Dial tone detection frequency – Lower Limit (Low)
Defaults: NA: 60, EU: 90, ASIA: 90
6BEC02(H) –Dial tone detection waiting time (20 ms)
Defaults: NA: 64, EU 64, ASIA: 64
6BEC03 to 6BEC04 – Dial tone detection monitoring time (20 ms)
Defaults
Area 6BEC03 6BEC04
NA F4 01
EU F4 01
ASIA F4 01
6BEC05(H) – Dial tone detect judge time (20 ms)
Defaults: NA: 64, EU: 1B, ASIA: 32
6BEC06(H) – Dial tone disconnect permission time (20 ms)
Defaults: NA: 11, EU: 0F, ASIA: 11