Main SP Tables-1
SM 5-31 D086/D087
System
Maintenance
1152 [Fusing Nip Band Check]
001 Execute -
[0 or 1 / 0 / 1]
Executes the nip band measurement between heating roller and pressure roller.
If the nip band width is not 8 mm, and fusing is not good, replace the pressure
roller or install a new fusing unit.
002
Pre-Idling Time *ENG
[0 to 255 / 240 / 1 sec/step]
Specifies the fusing rotation time before executing SP1109-001.
003
Stop Time * ENG
[5 to 30 / 20 / 1 sec/step]
Specifies the time for measuring the nip.
004
Pressure Position * ENG
[1 to 3 / 3 / 1 ]
Specifies the pressure position for measuring the nip.
1153 [Fuser Cleaning]
001 Compulsion execution - Execute the fusing cleaning mode.
002
Operation interval *ENG
[1 to 300 / 0 / 1 K/step]
Adjusts the execution interval for the fusing cleaning mode.
1K= 100 sheets
003
Control Temp. *ENG
[0 to 200 / 180 / 1°C/step]
Specifies the heating roller temperature for the fusing cleaning mode.
004
Page Count *ENG
[1 to 300000 / - / 1 page/step]
Displays the page counter for the fusing cleaning mode.