Main SP Tables-2
SM 5-53 D086/D087
System
Maintenance
2152
[Area Shad. Correct. Setting] FA
Adjusts the area correction value for each LD power.
The main scan is divided into 16 areas. However, the image areas are limited
from area 1 to area 14.
For BK and Magenta, area 1 is at the rear side of the machine (left side of the
image) and area 14 is at the front side of the machine (right side of the image).
For Cyan and Yellow, area 1 is at the front side of the machine (right side of the
image) and area 14 is at the rear side of the machine (left side of the image).
001 Area 0: Bk *ENG
This is for the synchronizing detection
board.
[50 to 150 / 100 / 1 %/step]
002 Area 1: Bk *ENG
003 Area 2: Bk *ENG
004 Area 3: Bk *ENG
005 Area 4: Bk *ENG
006 Area 5: Bk *ENG
007 Area 6: Bk *ENG
008 Area 7: Bk *ENG
009 Area 8: Bk *ENG
010 Area 9: Bk *ENG
011 Area 10: Bk *ENG
012 Area 11: Bk *ENG
013 Area 12: Bk *ENG
014 Area 13: Bk *ENG
015 Area 14: Bk *ENG
016 Area 15: Bk *ENG
This is out of the image area.
[50 to 150 / 100 / 1 %/step]