Main SP Tables-2
D086/D087 5-64 SM
009
Time *ENG
[1 to 1440 / 300 / 1 minute/step]
Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions.
010
Magnification *ENG
[0 to 10 / 0.1 / 0.01%/step]
Adjusts the magnification threshold for line position adjustment. If the length of
the main scan is changed by this amount since the previous MUSIC, then
MSUIC is done again.
011
Temp. 2 *ENG
[0 to 100 / 10 / 1deg/step]
Adjust the temperature change threshold for the line position adjustment (Mode
a: adjustment twice). The timing for line position adjustment depends on the
combinations of several conditions.
012
Time 2 *ENG
[1 to 9999 / 600 / 1 minute/step]
Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions.
013
Page: Power
ON:BW+FC
*ENG
[0 to 999 / 200 / 1 page/step]
Adjusts the threshold of the line position adjustment for BW and FC printing
mode at power-on. The line position adjustment is done when the number of
outputs in BW and color printing mode reaches the value specified with this SP
and the condition of SP2-193-008 or SP2-193-009 is satisfied.